キーワード、オーダーコード、製品コード、またはシリアル番号で検索してください(例:「CM442」や「技術仕様書」)
2 文字以上を入力して検索を開始してください。
product picture of the ultrasonic flow measurement instrument FLOWSIC100 Flare-XT

FLOWSIC100 Flare-XT
ultrasonic flow measurement instrument

Reliable gas flow measurement on flare stacks in petroleum refineries, chemical plants and natural gas processing

IFL1FX
Please Wait (spinning wheel)
価格の読み込み中
価格は一時的に表示されません
Price on request
価格を有効化
価格:情報を提供
機器をフィルタ表示/アプリケーションタスク
計測 / アプリケーションタスク

本製品の仕様を選定してCAD図面をダウンロード

  • 測定原理

    Ultrasonic transit time difference measurement

  • Measured variables

    Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity

  • Measuring range

    0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)

  • Max. Measurement error

    Volumetric flow, a. c.; 1 % ... 5 %
    Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value)
    0,5 % ... 1,5 % with spool piece and flow calibration
    Related to the measured value with ultrasonic technology (in the range ≥ 1.0 m/s (≥ 3.3 ft/s) to calibration range end value
     
    Mass flow rate a.c.; 2 % ... 5.5 %
    Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value)
    1,5 % ... 2 % with spool piece and flow calibration
    Related to the measured value with ultrasonic technology (in the range ≥ 1 m/s (≥ 3.3 ft/s) to calibration range end value)

  • Medium temperature range

    -196 °C ... +280 °C
    (-320 °F ... +536 °F)

  • Operating pressure range

    CL150 device flange (1) ATEX/IECEx: 20 bar(g)
    CSA: 16 bar(g)
    PN25 device flange (optional) (1) ATEX/IECEx: 20 bar(g)
    CSA: 16 bar(g)
    CL300 device flange (optional) (1) ATEX/IECEx: 20 bar(g)
    CSA: 16 bar(g)
    (1) Temperature dependent.

  • Nominal pipe size

    1-path measurement 4 ″ ... 86 ″
    2-path measurement 12 ″ ... 86 ″
    Other nominal sizes on request

  • Conformities

    ATEX: 2014/34/EU
    EMC: 2014/30/EU
    RoHS: 2011/65/EU
    PED: 2014/68/EU

  • Hazardous area approvals

    Interface Unit
    IECEx:
    Zone 1: Ex db eb ia IIC T4 Gb
    Zone 1: Ex db ia IIC T4 Gb
    Zone 2: EX ec ia IIC T4 Gc
     
    ATEX:
    Zone 1: II 2G Ex db eb ia IIC T4 Gb
    Zone 1: II 2G Ex db ia IIC T4 Gb
    Zone 2: II 3G Ex ec ia IIC T4 Gc
     
    NEC/CEC (US/CA):
    Class I, Zone 1, AEx d ia IIC T4 Gb
    Class I, Division 1, Groups B, C, D, T4
    Class I, Zone 2, AEx ec ia IIC T4 Gc
    Class I, Division 2, Group A, B, C and D, T4
     
    Sensors
    F1F-S/P/R:
    IECEx:
    Zone 1: Ex db [ia Ga] IIC T6 Ga/Gb
    ATEX:
    Zone 1: II 1/2 G Ex db [ia Ga] IIC T6 Ga/Gb
    NEC/CEC (US/CA):
    Class I, Division 1, Groups B, C and D, T4; 
    Class I, Zone 1, Ex/AEx d[ia] IIB + H2, T4;
     
    F1F-M:
    IECEx:
    Zone 1: Ex db [ia Ga] IIB T4 Ga/Gb
    ATEX:
    Zone 1:  II 1/2 G Ex db [ia Ga] IIB T4 Ga/Gb
    NEC/CEC (US/CA):
    Class I, Division 1, Groups C and D, T4; 
    Class I, Zone 1, Ex/AEx d[ia] IIB, T4;
     
    F1F-H:
    IECEx:
    Zone 1: Ex db IIC T6 Gb
    ATEX:
    Zone 1: II 2 G Ex db IIC T6 Gb
    NEC/CEC (US/CA):
    Class I, Division 1, Groups B, C and D, T4; 
    Class I, Zone 1, Ex/AEx d IIB + H2, T4;

  • Outputs

    Up to 6 outputs when using I/O modules (Option)
    16 bit:
    4 ... 20 mA
    7 V DC ... 30 V DC
    In accordance with NAMUR NE43
    Passive, galvanically isolated
    Reverse polarity protection

  • Digital Outputs

    Switching output:
    Up to 6 outputs when using I/O module (option)
    Electrically isolated
    Max. current: 70 mA
    Max. switching frequency: 50 Hz
    Max. input voltage: 30 V DC
    Max. saturation voltage at output: 0.5 V DC
    Switchable Namur/open collector
    Reverse polarity protection
     
    Digital output/Frequency output:
    Up to 12 digital outputs when using I/O modules (option)
    Electrically isolated
    Max. current: 50 mA
    Max. switching frequency: 10 kHz
    Max. input voltage: 30 V DC
    Max. saturation voltage at output: 1.8 V DC
    Switchable Namur/open collector
    Reverse polarity protection

  • Digital communication

    HART
    MODBUS
    FOUNDATION FIELDBUS